TROUBLESHOOTING CHART
Low High Pump Motor Reason and remedy
Vacuum Pressure Vacuum Pressure Overheat Overload for problem.
At pump ••Filter dirty.
Clean or replace.
At pump ••Muffler dirty.
Clean or replace.
At pump ••Vacuum line collapsed.
Repair or replace.
••Relief valve set too high.
Inspect and adjust.
•• Relief valve set too low.
Inspect and adjust.
••At pump At pump Plugged vacuum/pressure line.
Inspect and repair.
•• Vanes sticking.
Clean or replace.
•• Vanes worn.
Replace.
•• Shaft seal worn.
Replace.
•• ••Dust or offset powder in pump.
Inspect and clean.
•• Motor not wired correctly.
Check wiring diagram and line voltage.
Running at too high an RPM.
Check wiring diagram and line voltage.
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
- 269-926-6171
We have Gast Certified Service Centers throughout the world. For the most up-
to-date listing, contact one of our sales offices below:
Gast Hong Kong
Unit 12, 21/F, Block B
New Trade Plaza
6, On Ping Street, Shatin
N. T. Hong Kong
Ph: (852) 2690 1066
Fax: (852) 2690 1012
www.gasthk.com
European Sales & Service
Headquarters
Gast Group Limited
A Unit of IDEX Corporation
Unit 11, The I O Centre
Nach Road
Redditch B98 7AS
United Kingdom
Tel: +44 (0) 1527 504040
Fax: +44 (0) 1527 525262
www.gastmfg.com
www.jun-air.com
Gast Manufacturing, Inc.
P.O. Box 97
2300 Highway M139
Benton Harbor, MI 49022
Ph: 269/926-6171
FAX: 269/925-8288
www.gastmfg.com
Page view 7
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments