8
Low High Pump Motor Excess Reason and remedy
Vacuum Pressure Vacuum Pressure Overheat Overload Noise for problem.
••At Pump •• Filter dirty. Clean or replace.
•• At pump •• Muffler dirty. Clean or replace.
•• Valves dirty or valves bent.
Clean or replace.
•• Worn piston rings.
Repair or replace.
••• Relief valve set too high.
Inspect and adjust.
•• Relief valve set too low.
Inspect and adjust.
••At pump At pump •• Plugged vacuum/pressure line.
Inspect and repair.
• At pump Collapsed vacuum line.
Inspect and repair.
•• Low voltage, wonʼt start.
Check power source.
•••Voltage wrong.
Check power source.
•• •Worn rings/piston hitting cylinder.
Replace.
••Cylinder misadjustment.
Realign.
•• Leaky hose or check valve.
Replace.
•• • ••Dirt or liquid on top of piston.
Inspect and clean.
•• • • Motor not wired correctly.
Check wiring diagram/line voltage.
•• •Blown head gasket.
Replace.
T
ROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright ©2002 Gast Manufacturing Inc. All Rights Reserved.
PART NO. 70 - 3000 G442PL (REV-J)
World Headquarters
P.O. Box 97
2300 Highway M139
Benton Harbor, MI 49022
Ph: 269/926-6171
FAX: 269/925-8288
www.gastmfg.com
Gast Hong Kong
Room 6,9/F.
New Commerce Centre19
on Sum St, Shatin
N. T. Hong Kong
Ph: (852) 2690 1008
Fax: (852) 2690 1012
www.gasthk.com
Gast Group Ltd.
A Unit of IDEX
Corporation
Unit 11, The I O Centre
Nash Road
Redditch, B98 7AS
United Kingdom
Ph: +44 (0)1527 504040
Fax +44 (0)1527 525262
Comments to this Manuals